Client reviews
No reviews yet
Anguil Environmental provides highly-engineered, environmental equipment and service solutions that help clients solve complex industrial air and water challenges across the globe. We have been committed to protecting the environment with unmatched engineering, innovative equipment, guaranteed compliance, and reliable service since 1978.
Anguil Environmental provides highly-engineered, environmental equipment and service solutions that help clients solve complex industrial air and water challenges across the globe. For wastewater contaminants, Anguil delivers turnkey water treatment systems for industrial processes, manufacturing operations and remediation sites. Whether you need minor repairs, a system retrofit, or complete replacement of your entire treatment train, Anguil is a system integrator with the necessary process knowledge and technical staff to make your project a success. For unique wastewater challenges, we can perform bench trials at our wet lab or pilot testing onsite. Our collaborative and technology-agnostic approach ensures you will be selecting the treatment approach that best aligns with your business needs and decision criteria.
At their core, industrial air pollution control technologies capture pollutants and neutralize them so they aren’t released into the atmosphere. This two-step focus both reduces organizations’ emission footprints and eliminates potentially costly production disruptions or fines for non-compliance. We provide a comprehensive suite of thermal and catalytic oxidizer units that can provide this service. First, the units intake pollutants such as: -Emissions with undesirable odors -Hazardous Air Pollutants (HAPs) -Volatile Organic Compounds (VOCs) -Nitrogen Oxides (NOx) Oxidation technologies use time, temperature and turbulence to convert the pollutants into water vapor, carbon dioxide, and thermal energy. Every unit is designed to provide reliable, energy-efficient performance based on the unique needs and output of your facility. Our full offering of technologies allows Anguil to fully evaluate each application and recommend the best solution based on performance requirements and efficiency needs, without prejudice.
ImpactA global chemical manufacturer, facing a facility relocation and expansion, encountered significant challenges in managing increased wastewater volume containing hazardous cyanide. Anguil addressed this critical issue by providing an automated wastewater treatment system utilizing alkaline chlorination, validated through rigorous bench and pilot testing. Key Outcomes: Significant Cost Savings : Eliminated substantial hauling and disposal costs, providing an ROI within 14-16 months. Automated Efficiency : Integrated advanced automation, minimizing operator intervention and optimizing operational efficiency with proactive system notifications and remote monitoring capabilities. Safety and Compliance : Transitioned away from hazardous chemicals like ozone and peroxide, meeting stringent discharge standards (below 0.04 ppm). Validation and Assurance : Conducted comprehensive bench and pilot testing to confirm treatment effectiveness, operational reliability, and precise chemical dosing. Comprehensive Integration : Delivered a fully integrated, turnkey solution including engineering, installation, commissioning, training, and continuous aftermarket support. Anguil’s innovative wastewater treatment solution significantly reduced environmental risks, operational costs, and resource demands, enabling sustainable business growth and environmental compliance.
ImpactAs global demand for sustainable energy solutions rises, Lithium-Ion Batteries (LIBs) have become central to reducing individual and corporate carbon footprints. The increased use of LIBs in electric vehicles and residential solar power systems significantly supports environmental objectives. However, LIB manufacturing generates harmful Volatile Organic Compounds (VOCs) and Hazardous Air Pollutants (HAPs), presenting significant pollution control challenges. Anguil successfully addressed these challenges for a major LIB manufacturer by engineering a tailored pollution control solution capable of processing up to 70,000 SCFM of VOC-laden air without fossil fuel reliance. Leveraging advanced technology, Anguil installed three electrically heated Regenerative Catalytic Oxidizers (RCOs) combined with a zeolite concentrator wheel. This innovative system dramatically reduced VOC emissions by over 90%, achieving a remarkable 97% Thermal Energy Recovery (TER). Key Outcomes: Fossil-Fuel-Free Operation : Completely eliminated fossil fuel use by integrating electric heating elements in the RCOs, aligning with the facility’s strict environmental standards. High Efficiency : Employed a zeolite concentrator wheel that reduced airflow volume by 90%, significantly cutting downstream system size, capital costs, and utility consumption. Optimized Design : Installed compact RCO systems with low operational temperatures (600-800°F), resulting in reduced space requirements and minimal maintenance needs. Reliability and Redundancy : Provided an n+1 redundant arrangement, ensuring continuous compliance and operational flexibility during maintenance periods. Seamless Integration : Successfully installed systems within tight spatial constraints, leveraging modular design for simplified logistics and cost-efficient implementation. Anguil's innovative solution surpassed design expectations, demonstrating effective pollution control, energy efficiency, and sustainability in LIB manufacturing, setting a benchmark for future environmental compliance efforts.
Case StudyAs individuals and corporations continue to push towards smaller carbon footprints, the use of Lithium-Ion Batteries (LIB) has become increasingly prevalent. Specifically for individuals, the utilization of battery packs for all-electric automobiles and solar-powered home battery banks have continued to grow at a rapid rate. The manufacturing of these battery packs generates several air pollutants that must be treated prior to being released to atmosphere. One large supplier of LIBs faced a unique set of challenges at their main production facility. Three identical abatement systems were required, capable of handling up to 35,000 SCFM of emission laden air each. Electrically heated air pollution control systems are typically much smaller. Fossil fuels (natural gas, propane, fuel oil, diesel, etc.) of any kind are not allowed in the factory. Process gases consist of both ambient and hot air streams, both with very low concentrations. All abatement systems were to be installed indoors on the third floor of the factory with very tight footprint and height constraints. Manufacturing of complete LIBs requires several different processes and operations that produce Volatile Organic Compounds (VOCs) and Hazardous Air Pollutants (HAPs) at varying temperatures. For instance, making battery electrodes uses N-Methyl Pyrrolidone (NMP) which is a solvent the manufacturer can recover and reuse without treatment in a pollution control device. However, this supplier had additional module manufacturing lines and multiple e-coat paint lines with curing ovens where solvent recovery was not an option. This further complicated the compliance solution. Anguil was tasked with developing a compliance solution to capture and treat 70,000 SCFM of emission laden air with the following requirements: -Achieve a minimum 90% overall air pollutant reduction -Any heating requirements must be achieved without the use of any fossil fuel -Provide an n+1 arrangement for system redundancy during maintenance -Minimize all utility consumption to the greatest extent possible -Reduce overall system footprint, height, and weight to fit within facility restraints Anguil is one of the few industrial air pollution control providers that offers a full line of thermal and catalytic oxidizer technologies that also includes emission concentrators. The diverse technology offering allowed Anguil to evaluate each option and its applicability for the demanding project objectives. The first decision was to route all ambient process air sources to a zeolite concentrator wheel. The wheel uses a zeolite substrate to adsorb the VOCs and HAPs out of the process gases and onto the concentrator surface. A heated stream, approximately 10% the original volume, is used to desorb the pollutants from the wheel. The result is a highly concentrated stream that is one-tenth the original volume. This significantly reduces the size, capital and operating costs of the downstream oxidizers that are paired with the concentrator wheel. Anguil engineers made the decision to utilize Regenerative Catalytic Oxidizers (RCO) with electric heating elements to treat both the hot process stream from their curing ovens and the concentrated air stream from the concentrator wheel. This technology combination is often referred to as an RCTO. Employing catalyst inside a thermal oxidizer allows emission destruction to occur at much lower temperatures; 600-800°F (315-427°C) versus 1,400-1,500 °F (760-816°C). The lower operating temperature also provides for a much more reliable and smaller (physical size and KW rating) electric heating element. The RCO uses ceramic blocks as the heat transfer media allowing for 97% Thermal Energy Recovery (TER) from combustion. The combination of lower operating temperature and 97% TER made the RCO the best choice for minimizing utility consumption and ensuring low maintenance operation. All three oxidizer systems and the concentrator wheel were to be installed inside on the 3rd floor of a building still under construction under an existing mezzanine that provided only 15’ of overhead clearance. Anguil designed all individual pieces so they could be lifted three stories using an external elevator and fit through a narrow overhead door. All three units were installed inline and connected via common inlet and outlet manifolds to reduce installation costs. Once installation was complete, Anguil’s start-up technicians arrived onsite to complete final commissioning. Anguil’s technicians conducted operator training consisting of both “on skid” and classroom sessions. Test data has shown each of the systems is achieving greater than 90% overall emission removal and 97% TER. The Result: -Anguil was able to listen to the customer’s needs and the unique requirements of an oxidizer system that can process up to 70,000 SCFM of VOC-laden air without the use of fossil fuels. -The zeolite concentrator wheel was applied to the ambient temperature sources, greatly reducing the size of the downstream oxidizers and the associated utility requirements. -Selecting an electrically heated RCO eliminates the need for a fossil fuel fired burner, a customer requirement. The use of catalyst allows the oxidizer to operate at a much lower temperature than a thermal oxidizer, minimizing the size of the electric heating element. The RCO was also designed with 97% TER, further reducing the utility requirements and the size of the heating element. -The hot source from the cure oven was sent directly to the RCO inlet, having no negative impact on the operation and efficiency of the concentrator wheel. -Supplying three identical systems each sized to process 35,000 SCFM allows the customer to process up to 70,000 SCFM of VOC-laden air while operating in the required n+1 arrangement. -Each system was designed to minimize the footprint and height to the greatest extent possible, saving on valuable floor space inside the facility. -The system efficiency and effectiveness have exceeded the design specifications.
Case StudyA global manufacturer of key chemical ingredients used in a wide array of products including clothing, carpeting, automobile thermoplastics, computer cases, and sporting equipment, was planning a facility relocation and expansion that presented a significant wastewater treatment challenge. At their previous location, the manufacturer was using a perozone system to treat their cyanide-laden wastewater. However, the system as designed could not meet the rigorous discharge standards of the local Publicly Operated Treatment Works (POTW) on the order of 0.04 ppm. Further, they had abandoned the peroxide injection system to reduce the health and safety risks per a companywide mandate. The expansion required a relocation to a new facility, but the increased production would also triple the company’s wastewater volume. If they did not find an onsite treatment solution, the hauling and disposal costs were going to dramatically increase operating expenses. The Solution Nailing Down the Requirements Anguil collaborated with the client to understand their specific challenges and determine the project objectives. We gathered benchmark data at the existing facility to identify possible solutions that offer the best return on investment (ROI). Project engineers then worked with the customer to understand their decision-making criteria to evaluate only business viable treatment approaches. In this case, the client’s priority was to eliminate hauling and disposal costs of their cyanide-laden wastewater. With the expansion at a new facility, they expected their wastewater volume to triple, as well as the corresponding disposal costs. Secondly, they wanted a fully automated system with minimal operator intervention so they could focus on producing products. Third, they wanted to minimize the storage and handling of any noxious chemicals. Next, water samples were sent to the Anguil lab to validate the different technology considerations. Anguil typically identifies several potential treatment and process options which align with the client objectives, and after presenting these to the customer, collaboratively selects one or several to validate. Anguil proposed several oxidation schemes. The client preferred to move away from ozone and peroxide so alkaline chlorination was selected for this project. It is a well-known method with wide application to similar waste streams and is easily automated. To validate the treatment process, the customer elected for both a bench trial as well as a scaled pilot. For the bench work, the client provided 5 gallons of wastewater collected from their existing facility. Using the required caustic and bleach treatment protocol and measuring free HCN content via the USEPA Pyridine Barbituric Acid Method (Method 10265), test samples were returned which were below the POTW limit of 0.04 ppm. Based on the bench tests results, chemical dosing requirements and costs were easily established before the system was even installed. After the validation that the method would work, albeit on small sample volumes, the customer requested that Anguil perform a larger pilot study to both validate that larger batch treatments would perform similarly. For the pilot work, the client sent Anguil two (2) fifty-five-gallon drums of wastewater. Adapting an existing pilot system, the same reactions were performed at the previously determined set-points on 15- and 25-gallon batches. Again, final concentrations of HCN were below the required discharge limit. In addition to the further treatment efficacy validation, the chemical dosing requirements were used to estimate yearly operational expenses for the full-scale treatment system as well as size and design the required chemical reagent storage capacity. The final step in the process is the system design, realization, and installation. Anguil put together the proposal for a fully automated batch treatment system to handle their expected treatment volumes. The proposal contained specifics on many mechanical components including the tank, pumps and mixer sized as well as the advanced automation and controls – including integration with their existing infrastructure and DCS system – to meet their requirements. Additionally, the appropriate service options for installation, installation supervision, commissioning, and training were included. After the system was installed, Anguil performed a 3-day start-up and training including verification of the system’s ability to treat the wastewater. Anguil’s Aftermarket team will be there to service and support the client as needed. The Result Anguil’s approach to solving a client’s wastewater problem is to take a wholistic view of the challenge with a series of go/no go steps throughout the process. Project Engineers are always focused on the customer’s business objectives in a collaborative effort to define an efficient and cost-effective trial to validate treatment approaches that align with their objectives. Through the bench and pilot testing, we offer insight gained along with a comparison of pros/cons of the treatment approaches until we get to the treatment system that aligns with the client needs. As a system integrator with 35+ engineers and 60+ supporting personnel, we take a technology agnostic approach to help our clients get the system they want. In this case, the results from our effort: -Client walked through a collaborate process to ensure key decision criteria and objectives were met in a timely and cost-effective manner. -Customer was able to evaluate various oxidation treatment options that aligned with safety and cost parameters. -Lab and pilot validation trials confirmed treatment approach and provided operational expense estimates to client as requested. -Anguil provided a single-source system integration approach that included all engineering (Mechanical, Electrical, CAD, Project Engineering) and support services in-house to mitigate exposure to risk and deliver a fully integrated system with install, commissioning, and training support. -The treatment approach saved the client considerable amount of money versus hauling and disposal services; providing an ROI estimated in the 14-16 month range. -Anguil’s electrical engineering team developed the automation and controls to automate the batch-treatment process. This results in minimal human interaction and an extremely efficient process. It also proactively notifies them via text and email of system condition, need for chemical reorder, reporting and remote login capabilities. Note: At the time of bench and pilot testing this wastewater, Anguil was engaged with a second wastewater produced by the client. We followed a similar approach and validated treatment efficacy through lab and pilot studies. The result of onsite treatment for both wastewaters offered the client an incredible cost savings with minimal impact to resources.
GreenMasters Recipient No client reviews yet
If you have worked with Anguil Environmental Systems, Inc, you can be the first to write one. Reviews are checked before they go live.

Committed to Cleaner Air and Water
Fostering Sustainability, Building Connections: Through our platform, connecting with customers for your services and products is seamless and efficient.
View Pricing